Home Ion Chromatography Suppressor IC column Flash LC Flash column Prep HPLC HPLC PUMP HPLC spare SPE Spliter Software Sulfur analyser Portable Sulfur analyser Portable measurment Air quality monitoring Resistivitymeter AOX analyser TOX analyser TOC analyser Combustion IC KF analyser EasyH2O HiQ water Sample preparation Sonicator High pressure reactor Mineralisation Microwave reactor Peristaltic pump Peristaltic pump-2 About Service Newsletter Contact Vente Link Legal
Contact

YL9300 HPLC system

Excellent flow precision < 0,1%

Wide range of flow from 1 ul / min up to 5 ml/min ( analytical HPLC ) and from 1 ul /min up to 10 ml/min ( option)

Automatic piston back flushing

Quaternary solvent system including on line degasser

Automated Solvent compressibility compensation

Easy  maintenance and Auto diagnostic at start up

Multi parameter monitoring possibility and much more...

Included  UV-VIS detector:

Wavelength range: 190-600 nm (Standard) 190-900nm (Option)

Data collection rate: up to 50Hz

Light source: Deuterium arc lamp / Tungsten lamp addible for visible range (Option)

2-Order filter: Automatic filter switching

Bandwidth: 5 nm

Wavelength accuracy: ±1 nm, Wavelength precision: ±0.1nm, Linearity: >99.5% at 2.5 AU (acetone, 254nm)

Noise level: <±0.35 X 10-5 Abs/min, 254nm, dry cell ,Drift : <1 X 10-4 Abs/hour

Dispersion element: Concave grating, Seya-Namioka

Flow cell design: Cone type,Path length: 10 mm (Analytical cell) volume: 10 uL  

Pressure limit: 2000 psi (Analytical cell )

Optics and electronic diagnostic routine

Wavelength Verification: On demand via internal holmium filter

Analytical HPLC all in one

 YL9110 Quaternary Pump


Operating principle: Parallel dual-plunger pump, Low-pressure gradient

Control mode: Constant flow, Constant pressure

Compressibility compensation: Automatic

Flow range: 0.001-10ml/min

Flow rate accuracy : ≤1% at 1ml/min

Flow rate precision: 0.1% RSD at 1ml/min

Maximum pressure: 6000 psi > Operating range: 0-6000 psi up to 5ml/min  > Operating range : 0-3000 psi up to 10ml/min

Pressure pulsation : ≤1% at 1ml/min

Number of eluent lines: 4

Gradient formation: 4-channel mixing valve

Composition Precision: <0.1%

Composition Accuracy: <0.5%

Auto prime/purge

Communications: LAN

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, automatic voltage selection, 50/60Hz, ±5% , 70W

 YL9111 Binary Pump


Operating principle: X 2 Parallel dual-plunger pump, High-pressure gradient

Flow range: 0.001-10ml/min

Number of eluent lines: 2

Communications: LAN

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, 50/60Hz, ±5%, 140W

YL9120 UV/Vis Detector


Wavelength Range: 190-900 nm

Data collection rate: up to 50Hz

Deuterium arc lamp & tungsten lamp

2-Order filter: Automatic filter switching

Bandwidth: 5.5 nm

Wavelength Accuracy : ±1 nm

Wavelength Precision : ±0.1nm

Linearity: >99.5% at 2.5 AU (acetone, 254nm)

Noise level : <±0.5 X 10^(-5) Abs/min , 254nm, dry cell

Drift : <1 X 10^(-4) Abs/hour

Dispersion element: Concave grating

Warm-up period: 1 hour

Flow Cell Design: Cone type

Path Length: 10 mm (Analytical cell)

Cell Volume: 10 uL (Analytical cell)

Pressure limit: 1500psi (Analytical cell)

Wetted materials: 316 stainless steel, Quartz, Teflon

Analog Outputs:  Two, software selectable: Absorbance Energy, Sample Energy, Reference Energy Communications: LAN

Power-up Diagnostics: Optics and electronic diagnostic routine

Power-up Wavelength Verification: Automatic on power up via internal         holmium filter and D2 lamp

5-Point Wavelength Calibration: On demand via internal holmium filter and D2 lamp

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, 50/60Hz, ±5%, 100W

 YL9160 PDA Detector


PDA  A/D Resolution: 16bit

Slit Bandwidth:  1.7nm  Pixel Resolution: 0.9nm Channel: 1024

Wavelength: 190~950

Shield Optics

Analytical Cell

      - Path-length: 10mm

      - Pressure       : >1500psi

      - Volume         : 13ul

Dimension:   W: 385mm  H: 160mm  D: 565mm

Weight:  15Kg

Noise Level: +/- 0.00002 AU (Empty Cell, 1sec Rise Time, 254nm)  

Drift  : 0.0002AU/hr (Baseline Correction), 0.001AU/hr (Room Temp)


Wavelength Accuracy: <1nm (HY-1 Holmium Oxide Filter)


Sampling Rate: Max. 50Hz


 1~16 nm Spectral Bandwidth, Wide Spectral Range, Alternative Spectral Function


GLP Compliance:

 - Photometric Accuracy, Linearity, Noise Level, Drift - System Check,


Analog Output: 2 channel (Replaceable Dual Wavelength Detector)      

Valve Output:  2ch, Programmable Sampling (Fraction Collector Function Available )


Trigger Input: 2ch

Communication: TCP/IP, RS232C

Simultaneous Data Channel:  8 or Full Scan

Filtering: Bessel, RC, Aver. 0.01~10Hz


 YL9150 Autosampler (Alias)


Sound pressure level: LeAq < 70 dB

Working temperature: 10 - 40°C

Humidity: 20 - 80% RH

Safety and EMC compatibility: According to EC-directives; CSA (UL) approved

Power requirements: 95 - 240 Volt AC ± 10%; 50/60 Hz; 200VA

Sampling:

Sample capacity: 2 Micro Well Plates according to SBS standards; 96-well high/low

Loop volume: 1 - 5000 µL programmable, 10 mL loop optional

Dispenser syringe: 500 µL standard or 2500 µL for Prep option

Vial detection: Missing vial/well plate detection by sensor

Headspace pressure: Built-in compressor, but only for vials with septa

Switching time injection valve: Electrically < 100 msec

Piercing precision needle: ± 0.6mm

Wash solvent: External wash solvent bottle (bracket optional)

Wetted parts in flow path: SS316, PTFE (teflon), ETFE  (tefzel), VESPEL, PCTFE (Kel-F). Optional: PEEK

(10) Injection cycle time: < 60 sec. in all injection modes for 1 injection ≤ 100 µL including 300 µL wash / < 20 sec in partial loopfill mode for 1 injection of 10µL including 500 µL wash

 YL9101 Vacuum Degasser


Number of channel: 4 CHs

Maximum flow rate: 10ml/min per channel

> 0-2.0ml/min per channel for 70% Gas Removed from Methanol

Internal volume per channel: 925ul per channel

Materials in contact with solvent: Teflon AF, PEEK and Glass-filled PTFE

Safety & maintenance: Error detection

Dimensions: 385 X 80 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, automatic voltage selection; 50/60Hz, ±5%, 20W

Modular analytical HPLC

Download  info   Download  info